One, two, or emergency bilge pump?

General boating discussion
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

One, two, or emergency bilge pump?

#1

Post by Chtucker »

The boat is spec'ed out with one bilge pump.. I am thinking I should have either a mounted second pump or Rules emergency 4000/8000gph pump on board..

What is recommended?
User avatar
goatram
Donator 08, 09, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19
Posts: 1959
Joined: Wed Apr 09, 2008 11:53 pm
16
Your location: Stanwood, Wa
Location: Stanwood WA

Re: One, two, or emergency bilge pump?

#2

Post by goatram »

At least one per compartment. You do have water tight compartment?.
John Risser aka goatram
33' RBW with twin 250 Hondas (Aliens)
2015 Ford F350 Dually
Master of R&D aka Ripoff and Duplicate
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#3

Post by Chtucker »

I need to ask more questions... The monohull was a recent decision.
Chaps
Donator '09
Posts: 2246
Joined: Sun Jan 13, 2008 12:19 am
16
Your location: Seattle, WA
Location: Seattle, WA

Re: One, two, or emergency bilge pump?

#4

Post by Chaps »

Monohull now? Everything will drain aft to the center bilge area. Are you leaving it in the water? If yes I'd put 2 totally separate systems in at the transom, a regular one (1500) with an electronic switch and a 3700 with a conventional float switch mounted slightly higher than the electronic switch and equipped with a loud alarm. If trailering I'd just go with a single 1500.
1987 24' LaConner pilothouse workboat, 225 Suzuki
Image
please view and like: https://www.facebook.com/bottompainting/
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#5

Post by Chtucker »

We chickened out on the cat because of money, resale and trailering if we ever do.

From my reading what you described was what I was going to insist upon. They specified a single 2000gph. I was going ask for a 4000gph with a switch mounted higher. The 8000gph draws 30amps and I can't find a switch that would handle that load.

Or probably just 2 2000gph pumps and keep the 8000 as backup with alligator clips.
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#6

Post by Chtucker »

From the initial response from Armstrong today (Saturday) bulkheads with limber holes.

I am taking that you don't have any drainage holes John and have watertight bulkheads with separate pumps?

What is the Coast guard/abyc and what SHOULD be done?
User avatar
welder
Site Admin
Posts: 4672
Joined: Thu Jan 03, 2008 11:51 pm
16
Location: Whitesboro, Texas
Contact:

Re: One, two, or emergency bilge pump?

#7

Post by welder »

One 2K pump on a AUTOMATIC SWITCH, for it to die you have to loose the batteries.
One 2K pump on a MANUAL SWITCH.
One spare on board for just in case.

The 2K pumps are a minimum.
Of course make sure TIN COATED wire is used through out the boat with water proof connections and properly fused.

Are you adding a RAW WATER wash down pump? [Highly suggested] Be sure to make your wash down hose long enough to reach the head, trust me, it helps a bunch. :scuba:
Lester,
PacificV2325, Honda BF225
2386
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#8

Post by Chtucker »

Yes there is a wash down pump, plus pressurized water (shower), but no sink in the head.

I had a few mandates from the Admiral. Heat. So we will have a forced air furnace with defrost ducts and a wallas cooktop with blower. Second was, I am not sleeping where "poop" she was not that ladylike though :skipper: So separate cabin accessed head.

Pretty well decked out, but no electronics as of yet on delivery other than VHF and compass.

Port/starboard dive doors, dual stations, twin Honda 225s, macerator pumps on the two fish boxes, inverter, shore power, windlass, wipers on all the front windows, flip bench, dinette, 140 gallons fuel, 30 gallon fresh, 30 gallon black, LED lighting.

Pretty much the same as the original specs on the Cat, but $20k less.
User avatar
Sabs28
Donator '11 '12 '13 '14 '15
Posts: 648
Joined: Mon Mar 14, 2011 11:57 am
13
Your location: Wits End
Location: New Hampshire

Re: One, two, or emergency bilge pump?

#9

Post by Sabs28 »

You don't need to find a 30 amp switch to run the big pumps. Use the float switch to trigger a high current relay. I personaly plan on having 2 pumps on float switches with a manual overide switch for both.
Image
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#10

Post by Chtucker »

Sabs28 wrote:You don't need to find a 30 amp switch to run the big pumps. Use the float switch to trigger a high current relay. I personaly plan on having 2 pumps on float switches with a manual overide switch for both.
I figured the relay was ne more point of failure.

I am doing some reading now on flotation. It was not so much of an issue with a cat as it was two separate hulls. I hope to have a very safe boat.
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#11

Post by Chtucker »

This is Kevin's post that I was thinking about

http://aluminumalloyboats.com/viewtopic ... =Flotation

What I take from that is, watertight compartments in the bottom of the hull are not then best. I would never consider foam.

Two pumps, one on a higher float switch, a spare pump or maybe one of those high volume Rule pumps. The batteries are awfull high on the Armstrong. If they are under water, I want to be in the liferaft already.
User avatar
spoiled one
Donator '08 '09 '10
Posts: 1138
Joined: Mon Jan 14, 2008 4:48 pm
16
Your location: Anchorage, Alaska
Location: Anchorage, Alaska

Re: One, two, or emergency bilge pump?

#12

Post by spoiled one »

Chtucker wrote: 140 gallons fuel
Can they squeeze more fuel capacity in her? I know range is king up here. :thumbsup:
Spending my kids inheritance with them, one adventure at a time.

2010 AK Meet & Greet
Image
2012 AK Meet and Greet
Image
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#13

Post by Chtucker »

I was,told it would be tough... 140 should hopefully get me 200 mile range with a reserve. They were really reluctant at that. Standard is 120.
dawgaholic
Posts: 509
Joined: Thu Oct 06, 2011 9:20 am
12
Your location: Middle Georgia

Re: One, two, or emergency bilge pump?

#14

Post by dawgaholic »

With respect to bilge pump setups, one can read horror stories about failures on the boating forums. Are any familiar with this product and might it provide another option for your dilemma?

Water Witch
I only do what the voices in the Tackle Box tell me to.
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#15

Post by Chtucker »

dawgaholic wrote:With respect to bilge pump setups, one can read horror stories about failures on the boating forums. Are any familiar with this product and might it provide another option for your dilemma?

Water Witch
My intent was to use a Waterwitch switch, but use separate ones for each pump.
dawgaholic
Posts: 509
Joined: Thu Oct 06, 2011 9:20 am
12
Your location: Middle Georgia

Re: One, two, or emergency bilge pump?

#16

Post by dawgaholic »

Gotcha chtucker. Have you considered a fuel bladder for extending your range?

Here is a link to ATL Range Extension Bladders and some of the ways users have employed them. Many of the tournament fishing guys use them.

tht
I only do what the voices in the Tackle Box tell me to.
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#17

Post by Chtucker »

Yes, 95% of the time we will be in Sound/Coastal Washington. We do plan on 1-2 month trip to Alaska in a few years. A fuel bladder would be the ticket.
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#18

Post by Chtucker »

Should I insist on two through hulls or is a y acceptable?
User avatar
spoiled one
Donator '08 '09 '10
Posts: 1138
Joined: Mon Jan 14, 2008 4:48 pm
16
Your location: Anchorage, Alaska
Location: Anchorage, Alaska

Re: One, two, or emergency bilge pump?

#19

Post by spoiled one »

Chtucker wrote:Yes, 95% of the time we will be in Sound/Coastal Washington. We do plan on 1-2 month trip to Alaska in a few years. A fuel bladder would be the ticket.
It seems odd to me that a boat that size can only accommodate one 120 gallon tank. Must be a weight/balance thing. I just hate carrying fuel on deck.
Spending my kids inheritance with them, one adventure at a time.

2010 AK Meet & Greet
Image
2012 AK Meet and Greet
Image
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#20

Post by Chtucker »

I think it more of reluctance thing, I ran into when we discussing the Cat as well. I am not too worried with 140 gallons (they bumped it up from the 120 on my request). Having moisture in my tanks is a far bigger concern for me.
User avatar
spoiled one
Donator '08 '09 '10
Posts: 1138
Joined: Mon Jan 14, 2008 4:48 pm
16
Your location: Anchorage, Alaska
Location: Anchorage, Alaska

Re: One, two, or emergency bilge pump?

#21

Post by spoiled one »

Chtucker wrote:I think it more of reluctance thing, I ran into when we discussing the Cat as well. I am not too worried with 140 gallons (they bumped it up from the 120 on my request). Having moisture in my tanks is a far bigger concern for me.
Keep working on them. I have three 135ish gallon tanks. I don't fill all three very often, but it is nice to have them if I need them. Remember, they work for you. :beer:
Spending my kids inheritance with them, one adventure at a time.

2010 AK Meet & Greet
Image
2012 AK Meet and Greet
Image
User avatar
goatram
Donator 08, 09, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19
Posts: 1959
Joined: Wed Apr 09, 2008 11:53 pm
16
Your location: Stanwood, Wa
Location: Stanwood WA

Re: One, two, or emergency bilge pump?

#22

Post by goatram »

Chtucker wrote:I think it more of reluctance thing, I ran into when we discussing the Cat as well. I am not too worried with 140 gallons (they bumped it up from the 120 on my request). Having moisture in my tanks is a far bigger concern for me.
Ask that they install a water trap and a second fuel suction device in the tank. All it would take is a metal strap welded in the bottom at an angle aft of your main pick up. LaPush and Neah would be the two marinas that I have had heard and experienced water in the gas. I will be pulling the boat soon and checking my Fuel Tank Sump. A two or three inch tall strap installed at the bottom of the tank two inches fwd of the aft wall set at an angle aft. I wanted to install a bung at the back lower corner to be able to drain the fuel tank but that is a BIG NO NO per USCG Regs.
29'build26.jpg
29'build26.jpg (73.08 KiB) Viewed 13471 times
I have two water tight compartments in the front with the back two currently having a hole or two at the top at stern. I need to fix that this Winter. I have 4 bilge pumps; 2 2000 GPH and 2 1100 GPH Rule Pumps on Switches and Floats. Each has its own thru hull to dump overboard. No Y's.
John Risser aka goatram
33' RBW with twin 250 Hondas (Aliens)
2015 Ford F350 Dually
Master of R&D aka Ripoff and Duplicate
Chtucker
Posts: 444
Joined: Tue Jan 10, 2012 7:14 pm
12
Your location: Redmond, wa

Re: One, two, or emergency bilge pump?

#23

Post by Chtucker »

Got it on the pumps... two pumps (at least) two separate systems.

Fuel storage, I am having a conference call tomorrow as it is the prebuild meeting.. I will ask again.

I am really curious to know what the other builders are doing for "flotation"

The Eaglecrafts that I have seen are foamed, Duckworths are foamed. I don't want ANY foam, and Armstrong does use any.

Goat's boat has the watertight compartments. Kevin's post discussed them as well as his belief that he hasn't seen a boat have a hole ripped in it... Probably more have been lost to through hulls failing.

I want the "safest" for my family, so we of course have been picking up stuff along the way. I won't purchase a life raft or EPIRB till right before launch to have the most of their certification periods. I have a MOB alert system for the kids. I just picked up two mini-me kids size immersion suits. We ALL wear PFDs when around the water all the time. I can't ask them to and not us. We put in port and starboard dive doors. There will a pipe ladder on the transom and another boarding ladder for emergencies. I am really concerned about the families safety....

The lack of watertight compartments vs foam vs ?? is something I want to think about.

Howard
Chaps
Donator '09
Posts: 2246
Joined: Sun Jan 13, 2008 12:19 am
16
Your location: Seattle, WA
Location: Seattle, WA

Re: One, two, or emergency bilge pump?

#24

Post by Chaps »

pretty tough to get enough flotation in that size of boat to keep it afloat to say nothing about having any room left over for fuel
1987 24' LaConner pilothouse workboat, 225 Suzuki
Image
please view and like: https://www.facebook.com/bottompainting/
dawgaholic
Posts: 509
Joined: Thu Oct 06, 2011 9:20 am
12
Your location: Middle Georgia

Re: One, two, or emergency bilge pump?

#25

Post by dawgaholic »

Ok, more questions about this foam vs. no foam deal. Can you not meet the requirements for floatation using watertight compartments like Stabicraft does? I'm aware that under 20' specific floatation requirements may necessitate foam but my question is why, if sealed air-tight compartments can provide the reserve buoyancy required, or is that even possible?

Enough posts here damning foam lead me to ask, for like Jetty & others, Ima KISS kinda guy. From first hand witnessing of a friend's glass boat which encountered a pointy rock exposing the foam cored hull and void filling foam, stuff is nasty and his was well waterlogged. I know of the closed cell foam now utilized and sold as impermeable to water absorption but how can it be more buoyant than a sealed air compartment? Size matters and it may well be that in the smaller boats that makes foam the answer but perhaps I'm just not getting this....
I only do what the voices in the Tackle Box tell me to.